Sample Rate Range | 32 to 216 kHz |
Gain Error | -0.3dB |
Dynamic Range | > 138dB (-60 dBFS method) |
THD + N | < -130dB (0.00003%); 0 dBFS input |
Latency | 11 to 45 samples (network and input sample rate dependent). |
Supported Sample Rates | 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz (-4% / -0.1% / +0.1% / +4.167%) at 24 bit |
Clock Sources | Internal, Word Clock, DARS, AES input 1-2, AES input 9-10 or from Dante Network Master. |
External Word Clock Range | Nominal sample rate ±7.5% |
Channel Count | 16 x 16 AES/EBU channels |
Input and Output | 2 x DB-25 connectors (AES59 Combined I/O / Tascam Digital) |
Alternate Input (optional DARS) | 1 x Female XLR (replaces DB-25 channels 1-2) |
Alternate Output | 1 x Male XLR (duplicates DB-25 channels 1-2) |
Channel Count | 2 x 2 S/PDIF Channels (reduces AES/EBU input channels) |
Input | 1 x RCA phono socket (replaces DB-25 channels 3-4) |
Output | 1 x RCA phono socket (switchable, duplicates any DB-25 channel pair) |
Input | 1 x BNC 75Ω port (switchable termination) |
Output | 1 x BNC 75Ω port |
PSU | 2 x IEC Inputs with retaining clips. |
Network | 2 x etherCON connectors, also compatible with standard RJ45 connectors. |
Primary PSU (A) | Green LED. Illuminates when an AC input is applied and all DC outputs are present. |
Secondary PSU (B) | Green LED. Illuminates when an AC input is applied and all DC outputs are present. |
Primary Network | Green LED. Indicates that a network connection is present on primary port when in redundant mode. When in Switched mode, a valid network connection at either Primary or Secondary network port will cause this LED to illuminate. |
Secondary Network | Green LED. Indicates that a network connection is present on secondary port when in redundant mode. Not used in switched mode. |
Sync Locked | Green LED. When unit is network slave, shows valid network lock. When unit is network master, shows lock to indicated clock source. Flashing indicates invalid external clock selected and unit has reverted to internal clock. |
Sample Rate | Orange LED for each: 44.1 kHz, 48 kHz, x2, x4. |
Pull Up/Down | Orange LED. Indicates unit is set to operate on a Dante pull up/down domain. |
Signal Indicators | 16 Green LEDs, 8 input/8 output indicators. Illuminate @ -126dBFS. |
Clock Source | Orange LED for each: Internal, Word Clock, DARS, Input 1–2 and Input 9–10. |
Redundant | Allows unit to connect to two independent networks. |
Switched | Connects both ports to integrated network switch allowing daisy-chaining of devices. |
Height | 44mm/ 1.73" |
Width | 482mm/ 19.98" |
Depth | 263mm/ 10.35" |
Weight | 3.84kg |
PSU | 2 x Internal, 100-240V, 50/60Hz, consumption 30VA. |